Return to Inspections
NameFAIRMEADOWS SWIM CLUB
Address2810 EASTBURN RD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/16/2015
Final Score @ Grade
26
General CommentsIntent to Suspend issued for record keeping, lighting, ventilation, deck drains, trip hazards, fencing and gates. Pool has installed a tent enclosure over the pool. A heater was installed in October. Lighting/electrical completed at the pool. Footers installed on deck. No permits have been pulled for project. No code enforcement inspections have been completed at the pool. Will refer to code enforcement. Recommend to discontinue use of pool until plans are submitted and building and electrical inspections have passed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not being maintained on a daily basis. Record main drain checks, chlorine, pH and temp daily. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No No ladders installed. Ladders must be installed every 75 ft or less. Install ladders where required.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope at 60 ft. Corrected to 50 ft.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Front gate to pool does not self-close, self-latch. Repair to self-close, self-latch. Intent to Suspend issued. Baby pool not enclosed by fence. Taken down to accomodate the "tent enclosure" on both sides. Install fence to enclose perimeter of pool. Fence must meet rules. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No No deck drains inside of pool tent enclosure. Provide deck drains inside enclosure. Trip hazard at entrances to pool. Metal rod across entrance. Eliminate trip hazard. Intent to Suspend issued.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No No ventilation in indoor enclosure. Provided approved mechanical ventilation. Pool did not go through plan review and was electrical was installed without permits. Intent to Suspend issued. Deck lighting does not meet 10 ft candles. Provide adequate lighting. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room not enclosed. Pump room shall be enclosed in weatherproof structures with 7 ft ceiling, lighting, ventilation, etc. No cross/forced ventilation in chemical storage room. Provide ventilation. Pump room/chemical storage room not locked. Keep locked.