6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Vacuum cap removed. Vacuum hose adapter in place. Vacuum ports shall have self-closing caps designed to be opened with a tool. Corrected by operator. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Two skimmers missing weirs. Some baskets needed emptied. Maintain skimmers in good working order, clean baskets regularly. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gap > 2" under fence. Maintain fence with no gaps > 2" under fence. Corrected by operator. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Posted pool hours are 8AM to 10PM. Current permit restriction is no night swimming. Either restrict pool hours to daylight hours only, or provide at least 10 foot candles of lighting at all parts of the pool and pool deck. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in the pump room. Store chemicals in the chemical storage room only. Corrected by operator. |