16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
No |
Yes
|
No |
4-601.11(A) Equipment food contact surfaces and utensils shall be clean to sight and touch. -Pf. Observed multiple plastic pans with sticker residue present, dishes were stacked so that sticker residue was touching the food contact surfaces on the pans. CDI- PIC took items to dish area to be washed/rinsed/sanitized.
**REPEAT** -1.5-
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg , How to Test Sanitizer https://youtu.be/y0SjmnabFaY , and Cleaning and Sanitizing Food Contact Surfaces https://youtu.be/av1Rbh-lh08 . |
|
44
|
1
|
Utensils, equipment & linens: properly stored, dried & handled |
No |
Yes
|
No |
4-903.11(B)(1) Clean equipment and utensils shall be stored in a self-draining position that allows for air drying. Observed multiple stack of plastic and metal containers stored clean and stacked wet. **REPEAT** -1- |
|
50
|
0.50
|
Hot & cold water available; adequate pressure |
No |
No
|
Yes |
5-103.11(B) Provide sufficient hot water to meet the peak hot water demands.-Pf Observed hot water at all hand sinks reach on 88F to 90F. Observed that hot water at the 3-compartment sink reaches 88F. Facility is unable to provided enough hot water to meet peak demand. Facility has placed a work order. -0.5- 10 DAY VR REQUIRED. |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
No |
No
|
No |
5-501.113(B) Keep dumpster, outside waste containers covered with tight-fitting lids or doors. Observed the tops and doors open on dumpsters outside. EHS reminded facility to keep doors closed. -0- |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed wall/floor trimming missing in upstairs salad prep room. EHS observed a gap between the floor and the wall due to the missing trimming. **REPEAT** -1-
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed A/C vents throughout kitchen accumulating dust and residue. Increase cleaning frequency to avoid accumulation. **REPEAT** -1- |