Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameASCHER NORTH, THE
Address640 N CHURCH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/29/2025
Final Score @ Grade
26
General Comments15 - Ring buoy grab rope degrading. Given until due date for South Tower return visit on signage, Thursday September 4th . Replace ring buoy with USCG approved ring buoy. Rope tangled on ring buoy. Untangled during the inspection. Intent to Suspend issued for the following: .2537 - plug EQ lines per State requirements .2534/.2537 - pool rules signage indicates pool open until 9:00 pm - not approved for night swimming - correct signage or schedule night swimming verification. Krishaun Johnson present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Alkalinity and thiosulfate reagents expiring in August. Provide new reagents.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algae growth beginning on wall tiles. Continue to monitor and treat as needed.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One of two skimmer equalizer plugs in skimmers rusted out. Spoke with contractor who was supposed to complete the work when drains were done. A site visit would be made today, 8/29, to plug. Ensure plugged per State requirement. Pictures ok for replacement. Will verify when return visit made for the ring buoy.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck damage where slip resistant tread beginning to come up. Does not present a trip hazard. Monitor and repair if worsens. Deck shall be slip resistant. Deck lounge chairs <6 ft. to pool edge. Maintain 6 ft. clearance around the pool.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool rules signage indicates pool open until 9:00 pm - not approved for night swimming - correct signage or schedule night swimming verification. Intent to Suspend issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Original construction. If ever replaced, ensure installed per NSF requirement.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in men's restroom. One stall missing toilet paper. One sink slow to run. Ensure all fixtures in good repair. Provide soap and toilet paper. Toilet paper replaced during the inspection.