NameASCHER NORTH, THE
Address640 N CHURCH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/16/2019
Final Score @ Grade
16
General CommentsImmediate Suspension issued for pH. Once corrected, contact Katie Wilson at 704-309-5494 to schedule a return visit. Pool shall remain closed to public until a return visit is made. Noted - contrasting color band not to edge of wall. If plaster ever re-done, color band shall be within 1" of edge of step and wall. Pool is not approved for salt as primary chlorination. ITS uploaded prior to inspection. Attached to inspection sheet.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 7.0. Operator added chemicals which increased pH to over 8.0. Maintain pH at 7.2 to 7.8. Immediate Suspension issued. Pool log book indicated that pH was at 7.0 earlier in day with no corrective action. Pool shall be closed if chemistry not maintained. .2535(1) Maintain pH at 7.2 to 7.8.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer with build-up underneath turtle. Keep clean. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter rusted and appears to be stuck. Keep operational and replace as needed. .2518(g) Keep flow meter operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals being stored on pool deck, not in approved chemical storage room. No lighting in current chemical storage room. Chemical storage room not approved on pool deck. Utilize chemical storage in approved area. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.