Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMAA BEVERLY CREST
Address7201 SHANNOPIN DR
 
City/State/ZIP
CHARLOTTE NC 28270
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/24/2022
Final Score @ Grade
14
General CommentsNight swimming is not approved. 18 images attached to verify items for in filed verification are correct. NOTE: Flowvis flow meter installed face plate is absent. Other brand flow meter properly functioning in images at 98 gpm. Permit Restriction: Pump must remain set at 3450 rpm. Flow meter must remain operable with flow range at 86 gpm (turnover) to 98 gpm max due to pipe size restriction.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. - Observed minor debris on pool surface and on pool floor. CDI- CPO cleaned areas during the inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed leaf debris in skimmer baskets. CDI- CPO removed debris.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(a & d) Pump room shall be weatherproof, kept dry, free of standing water, and in good repair. Observed water damage to walls in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(k) Provide shatterproof mirrors. - EHS unable to verify mirrors are shatterproof in facility restroom near pool.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. - Observed hose bib near pool deck without a back flow prevention device.