NameEMBASSY SUITES AYRSLEY
Address1917 AYRSLEY TOWN BLVD
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/9/2025
Final Score @ Grade
26
General CommentsNote: Rope for ring buoy is original to construction. Recommend replacing prior to next inspection. Lane Anderson present during the inspection. Pump changed. Verified the following during the inspection. New pump approved. 1) Electrical finaled 5/29/2025. 2) New pump Pentair SuperfloVST 342002 set to 3450 RPM meeting permit restriction. Flow meter not installed per mfg. specifications. 3) All piping - 2" line for main drain, skimmer and return. 4) (1) 2017 and (1) 2008 A10RCFRxxx drain cover. 5) (1) Pentair TR100C filter 6) (4) returns 7) (2) skimmers with EQ lines plugged per State requirement. Note: Operator is bidding for new heater. Leak on current heater. Ensure permits have been pulled and finaled with Code Enforcement prior to use.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Total alkalinity, cyanuric acid and thiosulfate reagents expired. Obtain new reagents for accurate record keeping.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some build-up on tile line around pool, especially on depth markers. Keep walls clean and in good repair. Damaged plaster in multiple locations. Concrete is showing through. Pool floor and walls do not meet 50% light reflectance. Will require repair in future. Offsets do not appear to be >1/2" at time of inspection. Some sand on pool floor. Ensure cleaning as needed to maintain pool.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Step handrail loose. Tighten.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope at 24 ft. Multiple knots in rope that were undone during the inspection. At 26 ft. with correction.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some areas around coping missing grout. One area on coping with hole. Fill/repair grout areas prior to next inspection.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Calcium hypochlorite being used in feeder that is required trichlor tablets. Verified no calcium hypochlorite in feeder at time of inspection. Operator was able to locate a bucket of trichlor tablets and replaced in the feeder during the inspection. Do NOT use calcium hypochlorite in the Pentair chlorinator onsite as it may cause an explosion. No flow meter on the chlorinator. Original construction. If ever replaced, ensure flow meter is installed.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water on floor in chemical storage room due to leak at heater. Keep floor free of standing water.