5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Total alkalinity, cyanuric acid and thiosulfate reagents expired. Obtain new reagents for accurate record keeping. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some build-up on tile line around pool, especially on depth markers. Keep walls clean and in good repair.
Damaged plaster in multiple locations. Concrete is showing through. Pool floor and walls do not meet 50% light reflectance. Will require repair in future. Offsets do not appear to be >1/2" at time of inspection.
Some sand on pool floor. Ensure cleaning as needed to maintain pool. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Step handrail loose. Tighten. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy rope at 24 ft. Multiple knots in rope that were undone during the inspection. At 26 ft. with correction. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some areas around coping missing grout. One area on coping with hole. Fill/repair grout areas prior to next inspection. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Calcium hypochlorite being used in feeder that is required trichlor tablets. Verified no calcium hypochlorite in feeder at time of inspection. Operator was able to locate a bucket of trichlor tablets and replaced in the feeder during the inspection. Do NOT use calcium hypochlorite in the Pentair chlorinator onsite as it may cause an explosion.
No flow meter on the chlorinator. Original construction. If ever replaced, ensure flow meter is installed. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Water on floor in chemical storage room due to leak at heater. Keep floor free of standing water. |