Premises Information

Return to Inspections
NameEMBASSY SUITES AYRSLEY
Address1917 AYRSLEY TOWN BLVD
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/23/2025
Final Score @ Grade
20
General CommentsImmediate suspension issued for imminent hazard. Will make return visit after day of inspection to ensure chlorinator is working and no chlorine directly in pool. Contact Marie Daley at 704-507-6806 to confirm water quality is in compliance with chlorinator (no hand feeding) and visit will be made to lift suspension. Pool must remain closed with signage posted until suspension is lifted by Health Dept. “E” Immediate Suspension status

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. *Immediate suspension issued Operator removed pucks from skimmer. Will make return visit after day of inspection to ensure chlorinator is working and no chlorine directly in pool.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. Ladder missing endcap. .2521 Install ladders per manufacturer instructions. Ladder step missing non-slip tread. .2521(b) Ladders shall have slip-resistant tread.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope required 25’6”. Operator untangled and corrected.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorine pucks added a directly to pool. Could not verify chlorinator is working properly at time of inspection. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water under pump on floor. .2533(d) Pump room floor shall be kept dry and free of standing water.