3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. CPO corrected to 7.0. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
CA on records recorded as 200. This is calcium reading. Educated operator on records reflecting correct values in correct areas. Corrected through education.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Skimmer lines missing plugs in skimmer. Disable according to State recommendations. Allowing 30 days to correct due to no suction hazard.
*Contact Marie Daley at 704-507-6806 when in compliance to lift ITS |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Bag of dry chemicals stored on floor. Items within 3' of piping in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Operator moved chemicals off floor. Corrected. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Sink fixtures in restroom rusted and not in good repair. Soap dispenser not working at time of inspection. 2526(m) Keep restrooms and fixtures clean and in good repair.
.2526(j) Provide soap and soap dispenser, no glass, at each sink. |