Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameALEXANDER VILLAGE
Address9224 GRAHAM RIDGE DRIVE
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/9/2025
Final Score @ Grade
16
General CommentsNo night swimming. Pool has two main drains documented on PDSC and a third, smaller drain that is part of the main drain system according to the operator. This could not be confirmed during the inspection. New (2) Pentair TR140C filters confirmed during inspection. Rope around buoy is beginning to show signs of sun damage. Rope is still strong enough to withstand pulling. Recommend replacing buoy by 2026.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. pH tested at below 6.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Test kit had chemicals that expired in 2022 and 2023.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Ladder by 4’ deep section of pool was loose and not secured.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Window at far end of business center has a loose stopper that does not prevent window opening greater than 4”. Back office that was open and accessible during inspection has a window with that opens onto pool deck with no stopper or alarm. .2537(b) All gates and doors shall be self-closing, self-latching. Gate by front visitor parking lot does not self close.