| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Cl 0.2. Maintain at least 1ppm free chlorine in the pool. Corrected to > 10ppm. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
When cl rose to above 10ppm. Acid feeder dropped pH to 6.8. Maintain between 7.2 and 7.8. Calibrate control board. Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Incomplete records. Check daily Cl, pH, main drains. Check at least weekly TA and CYA. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Equalizer line cover sticks out > 2". Cover cannot extend more than 2" into pool. Install A112 approved cover. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Missing one weir. Install functional weir.Baskets full. Clean regularly. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder broken. Ladder missing endcaps. Maintain ladder in good condition. - Intent to suspend item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both gates not self-closing and self-latching. Make gates self-closing and self-latching. Intent to suspend item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck chairs too close to edge of pool. Maintain at least 6 feet clear walkway around pool. Corrected by operator. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Standing water on pump room floor. Leak in pump room. Fix leak.Heavy mold in pump room and chemical storage room. Impropper ventilation in both rooms. Install forced air ventilation in chemical storage room and in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Provide air gap for backwash. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower not working. Provide functional shower. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in men's restroom. Provide soap. |