Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameUNIVERSITY CROSSINGS APARTMENTS
Address9010 UNIVERSITY CITY BLVD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/4/2020
Final Score @ Grade
32
General CommentsPosted pool hours are 9 AM - 10 PM. Pool not permitted for night swimming. Change posted pool hours to reflect that pool closes before dark or schedule a pool lighting inspection. Unable to verify all the windows that open onto the pool deck. Ensure that all windows opening onto the pool deck are alarmed or are not capable of opening > 4". Intent to suspend issued. 16) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. Corrected to 7.5.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Low or no flow in some of the skimmers. .2518(k) The flow-through rate through any one recessed automatic surface skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrail loose. Maintain secure and in good condition.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No New US Coast Guard approved ring buoy with 50 foot throw rope. .2530(a) Provide ring buoy for 33 foot throw rope. Corrected by operator.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not self-closing and self-latching. 2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Trash can stored too close to pool deck. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Corrected by operator.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. Flow meter installed beside an elbow. Appears to be sufficient space to properly install a flow meter per manufacturer's instructions. .2518(g) Install flow meter on return line per manufacturer instructions. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak at flow meter. .2533(d) Pump room floor shall be kept dry and free of standing water.