NameUNIVERSITY CROSSINGS APARTMENTS
Address9010 UNIVERSITY CITY BLVD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/29/2019
Final Score @ Grade
22
General CommentsPosted pool hours are 9AM - 10PM. Pool not permitted for night swimming. Change posted pool hours to reflect that pool closes before dark. Unable to verify all the windows that open onto the pool deck. Ensure that all windows opening onto the pool deck are alarmed or are not capable of opening > 4". Valve float assemblies in the skimmers were all locked closed from when tile work was done. This effectively turned the skimmers off and pulled water from the equalizer lines. When the water drops below the skimmers you will need to manually open up all of the valves on these assemblies once the water level has been restored so that the skimmers can function properly. Flow meter installed near an elbow. Recommend installing per manufacturer's instructions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing. Corrected by operator. Most skimmers not functioning. All but one corrected. .2518(k) The flow-through rate of any one recessed automatic surface skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50. - Intent to suspend item. Pop-up cover installed on the return line in one of the skimmers. Removed by the operator.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope 31 feet long. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Corrected by operator to 33 feet.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gaps > 2" under the fence. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Many of the directional arrows and labels are no longer visible. .2518(d) Piping and valves shall be labeled with color codes or labels.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Restrooms locked. Provide access to the restrooms when the pool is open.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One of the skinks with a leaky drain. .2626(m) Keep restrooms and fixtures clean and in good repair. One of the restrooms did not have soap. .2626(j) Provide soap and soap dispenser, no glass, at each sink.