NameMAA AYRSLEY
Address9005 LENOX POINTE DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/7/2015
Final Score @ Grade
16
General CommentsCorrection to L. Boyes (EHS) 3/11/15 inspection & the inspection before this conducted by K. Wilson (Sr. EHS); Since the pool barrier was constructed prior to 5/1/10 & the horizontal members of the barrier/ fence are not <30", the barrier is allowed to vary from .2528(a)(4). SEASONAL POOL PERMIT CAN BE ISSUED.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Pool records indicate that cyanuric acid levels are only being recorded one time per month. ** Check & record at least one time per week.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrail loose at stairs (cabana end of pool). ** Secure. Two ladders ~6.5" to 7" from pool wall. ** Clearance should only be 3" to 6"; however, problem cannot be corrected without raising ladders due to slope of pool wall.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damaged coping near 1' marker & sunken bricks at autofill. ** Repair.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Multi-port valve handle broken off at one filter. ** Replace broken parts.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals being stored in equipment room. ** Store in chemcial room provded. Forced air vent in equipment room inoperable. ** Repair.