NameCENTRAL POINTE
Address4933 CENTRAL AVENUE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/18/2026
Final Score @ Grade
12
General CommentsPermit Restriction - Flow meter must remain operable with flow at 93 gpm to 104 gpm to meet turnover and flow restriction of the 2" pipe. Flow greater than 119 gpm is Suction Hazard for drain covers. Filtration Main Drains Expire - 5/9/2030. Feature Main Drains Expire - 4/15-2030. Note: Grill and seating area not pool barrier. Pool barrier around exterior of grill and pergola. Main drain covers expire 5/9/2030 equalizer line covers expire 4/15/2030 Pool is not approved for night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed ladder to be loose and need to be repaired. Correct the ladder.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed underwater light fitting to be unsecured. Observed vacuum line fitting to be missing with the suction off. The vacuum line cover needs to be replaced. 30 day I.T.S. Issued. Deadline for correction is 4/17/2026. Failure to correct the issue may result in closure of the pool.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed door to the pool deck that is usually kept locked and alarmed to be unlocked with the alarm not working. Door was locked and the alarm will be reactivated. -CDI. Observed fence to be not built to current specifications. Pool built in 1972.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap for the backwash line.