Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCENTRAL POINTE
Address4933 CENTRAL AVENUE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/29/2025
Final Score @ Grade
8
General CommentsPOOL HAS PASSED INSPECTION AND BEEN ISSUED PERMIT DECAL. POST PERMIT DECAL AND PAPER POOL PERMIT DOCUMENT AT THE POOL. THE PAPER PERMIT SHOULD BE AVAILABLE WITHIN 1-3 BUSINESS DAYS ON THE HEALTH DEPARTMENT POOL WEBSITE. NEW PDSC FORM INFORMATION WAS VERIFIED DURING THE INSPECTION. PERMIT RESTRICTIONS: FLOW METER MUST REMAIN OPERABLE WITH FLOW 93 GPM TO 104 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF THE 2” PIPE. FLOW GREATER THAN 119 GPM IS SUCTION HAZARD FOR DRAIN COVERS. MAIN DRAINS EXPIRE 5/9/30 EQ LINE COVERS EXPIRE 4/15/30

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope to be 49 feet long. Rope must be 50 feet long. Rope was corrected by changing the knot to take up less rope in the knot itself. -CDI.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No air gap in backwash line. Observed backwash process to flood the pump room. This should not occur. Correct the backwash drain to handle the flow of the backwash process. This type of correction may require plumbing work and plumbing permits/plumbing inspections.