Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCENTRAL POINTE
Address4933 CENTRAL AVENUE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/27/2024
Final Score @ Grade
14
General CommentsEnsure that glass is not being brought into the pool. Observed several crown cap bottle caps around the deck and glass bottles in the trash can. Correct the pool rules sign to read that the pool is open “dawn to dusk” as was previously written. Pool does not currently have a night swimming approval. Pool has two Paramount SDX2 main drain covers and three Aquastar A8R equalizer line covers. These all expire in June of 2025. They must be replaced with covers that are approved for the required flow rates and the PDSC paperwork submitted and approved by the Health Department prior to expiration. Be aware that flow rates for the covers may be changed by the manufacturer. Be sure the covers used match the required flow rates. Observed the pump motor to be set to 3150 RPM. It must remain at 3110 RPM due to the flow restrictions of the system. It was corrected. Ensure it stays set at 3110 RPM as required.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed pool interior light to be slightly pulled away from the wall of the pool. Repair this before it becomes worse.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed throw rope to be 55 feet long. Corrected to 50 foot length as required for this pool. Observed ring buoy to be getting worn and damaged. A replacement has been order. Swap out the new buoy when it arrives and keep the rope length 50 feet long from the attachment point. -CDI
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at backwash line.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(a) Post a shower sign visible upon entrance to the pool. Observed shower sign to be blocked from view on much of the deck due to the new pergola blocking the sight line. Provide another shower sign were it can be clearly seen.