3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH to be 6.8 or lower. pH must be 7.2-7.8. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 2 skimmers out of 3 missing weirs. Replace the weirs. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed rope on buoy to be 46ft. 50ft. rope length is required. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Observed pool light housing to be missing entirely. This presents a physical hazard. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Observed salt system to be flashing "LO SALT" and back-up cl2 feeder disconnected. Observed cl2 tablets in skimmer baskets. This is not allowed as this situation presents a hazard. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed pump and filter to be turned off at the time of arrival. Pump system must work properly. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no backwash line air gap. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
Observed hose bibb in need of backflow preventer. |