NameSILVER COLLECTION AT WATERFORD
Address11926 JOLEEN CT
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/14/2024
Final Score @ Grade
12
General CommentsInspection conducted with CPO Lucas Markovic. “WARNING - NO LIFEGUARD ON DUTY” sign heavily faded. Recommend replacing. Ensure new sign is in at least 4” lettering.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Two skimmers with loose skimmer lid collars. Glue no longer holding in place. .2518(k) Surface skimmers shall be installed per manufacturer's instructions. One weir missing. .2518(k) Replace missing weirs. Some skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both ladders missing some non-slip treads. .2521(b) Ladders shall have slip-resistant tread. One ladder loose. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door to pool deck doesn’t latch. .2528(a) Ground level doors shall be self-closing and self-latching. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Fan not working in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.