2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine 0.5 ppm. Maintain at least 1ppm free chlorine in the pool. Operator unable to raise chlorine levels before end of inspection. - Immediate suspension item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Algae growing on pool walls and floor. Maintain pool free of algae. - Intent to suspend item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Some of the windows missing brackets, allowing windows to open all the way. Ensure that windows opening on to the pool deck are not capable of opening more than 4 inches. - Intent to suspend item. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Salt levels low, using backup erosion feeder to chlorinate the pool. Maintain proper water chemistry and ensure chlorinator is working properly. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan in chemical storage room not functioning. Provide either cross or continuous forced air ventilation in the chemical storge room. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Water line to shower turned off. Pipe on shower cracked and leaking. Provide functional shower. |