Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVA SOUTHEND
Address335 DOGGETT STREET
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/9/2017
Final Score @ Grade
24
General Comments2 - General Comment - Chlorine high and bleached out low chlorine test kit. Greater than 10 ppm. Recommend using less than 10 ppm chlorination to eliminate skin irritation. 6 - General Comment - One screw missing from main drain. Replace. Drain has 3 of 4 screws. 22 - General Comment - Emergency phone has listed phone automatically dials 911. Remove labeling as phone is a push to call phone. Intent to Suspend issued for record keeping and log book, No Diving marker, Fencing and Gate, Night Swimming signage and chlorination system.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No log book and test kit. Record chlorine, pH and main drain checks daily. Cyanuric acid and alkalinity weekly. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Severe etching in pool floor and walls. Keep in good repair.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No One No Diving marker loose. Secure to pool deck. Intent to Suspend issue.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No >1/2" within 18" of pushbar. Plexiglas was installed previously and has since broken off. Provide meshing, solid piece so provides no greater than 1/2" within 18" of the latch mechanism. 44" between horizontals on fencing without mesh. Maintain at least 45" between horizontals. Repair with meshing or solid piece. Electrical boxes on outside of fence provide foothold. Lower than 45". Provide angle over electrical GFCI to eliminate foothold. Intent to Suspend issued for all listed items.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool hours indicate 9:00 am to 10:00 pm. Lighting provided in pool and on deck but not adequate lighting. Provide at least 10 ft cancles of light or limit hours to dawn to dusk. Intent to Suspend issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No New chlorination system installed. Automated system. Verified in field and does not turn off when pump turns off. Repair so that chlorination system turns off when pump turns off. Intent to Suspend issued.