NameAURORA TOWNHOMES
Address1347 BRIAR CREEK RD
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/10/2025
Final Score @ Grade
8
General CommentsPOOL IS NOT APPROVED FOR NIGHT SWIMMING. OBSERVED SIGN THAT STATED POOL HOURS WERE 10AM TO 8PM. POOL HOURS CANNOT REFLECT ALLOWING THE POOL TO BE OPEN AFTER SUNSET OR BEFORE SUNRISE. IF YOU WISH TO HAVE THE POOL EVALUATED FOR NIGHT SWIMMING, CONTACT C. ELMORE AT 704-507-6814 TO SCHEDULE EVALUATION. WITHOUT NIGHT SWIMMING APPROVAL, POOL CANNOT BE OPEN AFTER DUSK OR BEFORE DAWN. PERMIT RESTRICTIONS: FLOW METER MUST REMAIN OPERABLE. FLOW REQUIRED AT 3450 RPM WITH FLOW METER READING NO GREATER THAN 104 GPM TO MEET FLOW RESTRICTION OF THE RETURN PIPE. TURNOVER REQUIRED AT 100 GPM. PUMP IS NOT MEETING TURNOVER. IF CLARITY ISSUES MAY REQUIRE CHANGE IN THE FUTURE. IF FLOW METER EXCEEDS 119 GPM SUCTION HAZARD DUE TO DRAIN COVER FLOW RESTRICTION. MAIN DRAIN COVERS EXPIRE 5/9/2030 EQUALIZER LINE COVERS EXPIRE 9/30/2029

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 2 eyeball return fittings missing. All others were in place. No Permit Action taken. Replace the fittings.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence with gaps > 4" through the fence due to bent /damaged vertical members. .2528(a) Provide no openings in fence and/or gate greater than 4"x4".