3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 8.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.3. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One eyeball fitting missing in the corner of the pool. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4".
Pre-2010 fence with wire meshing installed on one section of fencing creating hand/footholds. Mesh with openings > 1.75". .2528(b) Decorative cut-outs on fence and/or gate shall not exceed 1.75 inches. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pump basket cracked, gap between lip and basket. .2518(e) The circulation system shall include a strainer to prevent hair, lint, and other debris from reaching the pump with openings not more than ¼ inch.
No spare pump basket provided. .2518(e) Provide a spare basket for pump.
Eyeball fitting installed on second vacuum line. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Inadequate ventilation in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Some items stored up against filter and piping. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for the backwash line. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in women's restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
No toilet paper in men's or women's restroom. .2526(l) Provide toilet paper and dispensers in restrooms. |