Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAURORA TOWNHOMES
Address1347 BRIAR CREEK RD
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/15/2020
Final Score @ Grade
10
General CommentsPOOL HAS PASSED INSPECTION. STICKER ISSUED. POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” PAPER PERMIT WILL BE AVAILABLE ON-LINE SO THAT IT CAN BE PRINTED OUT BY THE FACILITY MANAGEMENT. IT MUST BE PRINTED OUT AND POSTED WHERE IT IS VISIBLE FROM THE POOL DECK AREA. NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING C . ELMORE VERIFIED THE IN-FIELD PLAN REVIEW ITEMS. 1. PUMP IS AN INTELLIFLO VSF 011056, 3HP PUMP SET TO 3110RPM, SPEED 4. IT IS NOT 2HP AS LISTED IN THE PDSC SPREADSHEET. THIS MAY REQUIRE CORRECTION ON THE PDSC FORM. IT WAS NOT TAKEN AS A VIOLATION. 2. MAIN DRAIN, SKIMMER, AND RETURN LINES ARE ALL 2" PIPE. 3. MAIN DRAIN COVERS ARE TWO PARAMOUNT SDX2 COVERS. 4. EQ LINE COVERS ARE FOUR AQUASTAR 6HPHAXXX COVERS. 5. FILTER IS A TR140C, NOT A TR100C. AFTER DISCUSSION WITH SENIOR SPECIALIST OF MCHD IT WAS DETERMINED THAT THIS WAS ACCEPTABLE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 1 weir missing out of 4 total skimmers. No Permit Action taken.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gaps in the fence greater than 4 inches. Fence builit prior to 2010. No Permit Action taken.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap in backwash line.