2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed 0.0ppm chlorine. Observed salt system not functioning properly at the time of arrival. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH to be 8.0. pH must be 7.2-7.8 |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed some days in September and October to be missing from the log book. Proper daily records must be kept. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed flow meter stuck. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed fence and gate damage resulting in gaps >7" and 1 gate not self-closing/self-latching. Repair the fence and gate. Gate and fence fixed. -CDI |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Observed warning sign improperly worded and to have lettering smaller than 1 inch. |