| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
4
|
6
|
Water quality: water temperature of heated pool |
No |
No
|
No |
Pool water > 90F. Maintain at no more than 90F. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No temperature or main drain checks for November. Check at least daily Cl, pH, main drains and temperature. Check at least weekly total alkalinity and cyanuric acid if used. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Main drains with only 2 screws. Install per manufacturer's specifications. - Immediate suspension item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Provide non-slip surface for steps. Ensure that non-slip contrasting color band stays in place. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Water level below the grates on the overflow system. Maintain proper water level. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Handrail loose. Maintain secure and in good condition. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck chairs and other items too close to pool. Maintain at least 5 feet clear walkway around the pool. - Intent to suspend item. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Underwater lights not functioning. Provide underwater lights. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone unplugged. No dialing instructions. Provide functional emergency phone with posted dialing instructions, address, and phone number. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace.
Water level below gutter returns, disrupting water surface. Maintain proper water level. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in storage room on the pool deck. Room with inadequate ventilation and no lighting with other items. Store chemicals in approved location.
Multiple leaks in pump room. Fix leaks. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Provide air gap for backwash. |