Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLE MERIDIEN HOTEL CHARLOTTE
Address555 S MCDOWELL ST
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/30/2015
Final Score @ Grade
36
General CommentsPOOL CLOSED FOR SWIMMING

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No Observed water too cloudy to be safe. I.S. Issued.
2 6 Water quality: disinfectant residual provided by No No No Observed cl2 to be 0.0ppm in pool. Pool must be at least 1.0ppm. I.S. Issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed no records kept since September 2015. Daily and weekly checks must be made and recorded. Monthly record must be kept.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed pool lining chipping and bubbling up. Repair it.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Observed more than 25ft. between depth markers. Observed deck depth marker to say "5FT" and sidewall to say "4FT". Correct this.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed throw ropes to be 31ft. and 28ft. They shall both be 33ft. I.S. Issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed pump room floor wet from leaks. Observed chemicals stored in room with no ventilation.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at backwash line.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Observed no floor drain or hose bibb in pump room.