23
|
1.50
|
Proper date marking & disposition |
Yes |
No
|
No |
3-501.18 Discard the food requiring date labels once time/temperature window has expired, if it is not been labeled, or if the label is incorrect. -P
3-501.17 Date mark/label all TCS foods that are ready-to-eat once opened or prepared and held more than 24hrs. -Pf
Observed three packs of deli meat and one package of swiss cheese past the 7-day date mark. Observed one package of opened lettuce without a date mark. CDI - Manager discarded all deli meats and cheese. Lettuce was date marked. |
|
39
|
1
|
Contamination prevented during food preparation, storage & display |
No |
Yes
|
No |
REPEAT
3-305.11 Store food in a clean, dry location, not exposed to contamination. Keep at least 6 inches above the floor. Observed boxes of food with a build-up of ice on them from the leaking walk-in freezer compressor. |
|
40
|
0
|
Personal cleanliness |
No |
Yes
|
No |
REPEAT
2-402.11 Use head coverings, beard guards and clothing to restrain body hair from contacting exposed food, equipment, and utensils. Observed one employee preparing food without a hair restraint. Improvements made from previous inspection. |
|
41
|
0
|
Wiping cloths: properly used & stored |
No |
Yes
|
No |
REPEAT
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses. Observed two wet wiping cloths stored on prep surfaces. Improvements made from previous inspection. |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
REPEAT
4-501.12 Resurface or replace cutting surfaces that can no longer be effectively cleaned and sanitized.
4-501.11 Maintain equipment in good repair.
Observed a deeply stained cutting board on the prep cooler. Observed a leaking walk-in freezer compressor. |
|
48
|
0
|
Warewashing facilities: installed, maintained & used; test strips |
Yes |
No
|
No |
4-302.13 (B) Provide an approved Max/Min thermometer for testing sanitizing temperatures in hot water warewashing machines. The thermometer must be readily accessible. -Pf Establishments dish machine thermometer is broken. CDI - Manager was able to temporarily repair and a new one has ordered a new one. |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
No |
No
|
No |
5-501.114 Drains in dumpsters and waste containers shall have drain plugs in place.
Observed a broken dumpster drain plug. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
REPEAT
6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Observed cracked and missing sections of tile at the entrance to the walk-in freezer.
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure.
Observed food and microbial residue on the walls behind the dish machine. |