Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Logs not maintained on 3/17. Maintain chlorine, pH and main drain checks daily.
Total alkalinity and thiosulfate reagents expired. Replace expired reagents. Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer basket damaged. Basket was stuck in skimmer upon arrival. Ensure skimmer baskets are removed daily for cleaning. Replace basket. Intent to Suspend issued. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
8 ft. depth marker on deck upside down. Repair/adjust depth marker so legible while standing on deck. Intent to Suspend issued. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Screw missing from bottom of step handrail/step handrail loose. Replace screw and tighten handrail. Intent to Suspend issued. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Light not flush to wall in shallow end. Light shall be flush to wall so not to present a location for finger entrapment. Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Coping cracked to right of deep end skimmer. Repair coping. Intent to Suspend issued.
Pavers no longer sealed within 6 ft. of pool edge. Reseal prior to 2025 operating permit - May 31st 2025. Permit will not be issued if not complete. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator inlet. Original construction. If repaired/replaced, ensure flow meter installed per mfg. instructions. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Provide hose bib within 50 ft. Original construction.
No floor drain restrooms. Provide floor drain. Original construction.
Could not view men's restroom at time of inspection. |