5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records on one day in December. Cyanuric acid was consistently recorded above 100 ppm. Cyanuric acid should be kept at 100 ppm or lower. Cyanuric acid was tested at 70 ppm during inspection. Ensure cyanuric acid is being accurately recorded on a weekly basis. Observed expired thiosulfate reagent. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris. Observed debris in bottom of pool. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Skimmer lids need a hole in the top for venting gases. New skimmer lids were cut pavers and two of the three were missing vent holes. Intent to Suspend. |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
.2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Observed safety rope with floats bunched at one end. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Polymeric sand missing from some areas of pavers. Reseal within 6 feet of pool edge prior to 2024 operating season.
Observed damaged coping on edge of pool by deep end. Intent to Suspend. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator inlet. Original construction. If repaired/replaced, ensure flow meter installed per mfg. instructions. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Mirrors in restroom could not be verified as shatterproof. Mirrors shall be shatterproof. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Provide hose bib within 50 ft. Original construction. |