8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer in deep end of swimming pool not operational. Pool square footage is 740 sq ft per records. Only two skimmers required per rules. Continue to monitor. If floating debris becomes an issue, pool may be required to repair.
Travertine paver used as skimmer lid. Per NSF approval, skimmer lids shall be vented. Operator removed one string to skimmer to provide vent. All other skimmers had vent in place. |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
Divider rope with all floats pushed to one side. .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some damage to pavers throughout. All sections where damaged seem to be secure. Continue to monitor and patch/repair as needed. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator inlet. Original construction. If repaired/replaced, ensure flow meter installed per mfg. instructions. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Mirrors in restroom could not be verified as shatterproof. Mirrors shall be shatterproof. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Provide hose bib within 50 ft. Original construction.
No floor drain in restrooms. Provide floor drains in restrooms. Original construction. |