Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFAIRFIELD INN AND SUITES
Address201 S MCDOWELL ST
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/17/2021
Final Score @ Grade
16
General CommentsBill Moore present during the inspection. No signature due to covid restrictions. Intent to Suspend issued for flow meter.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer in deep end of swimming pool not operational. Pool square footage is 740 sq ft per records. Only two skimmers required per rules. Continue to monitor. If floating debris becomes an issue, pool may be required to repair.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Table at 5 ft. from pool edge. Moved during the inspection. Maintain 6 ft. clearance around swimming pool. Debris under table stand when moved. Clean deck and keep free of debris.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operable. Pool has TR100c filter and 2" piping. Limitation on flow for pool. Flow shall not exceed 100 gpm. Repair flow meter and ensure flow at no greater than 100 ppm. Intent to Suspend issued.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Mirrors could not be verified as shatterproof in restrooms. Stand-up mirrors included. Ensure all glass in restrooms is shatterproof glass.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib in restrooms. Provide hose bibs in restrooms with backflow prevention. Original construction.