14
|
0
|
Food-contact surfaces: cleaned and sanitized |
Yes |
No
|
No |
4-602.11 Clean the equipment and utensils used with TCS foods as required to avoid contamination. -P Observed can opener blade with accumulated food residue. Item cleaned during inspection. |
|
31
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf Observed mac n cheese cooling in an upright cooler while covered in plastic wrap. Item was vented by EHS. Proper cooling procedure would be to vent the food items such that cold air from the cooling equipment is able to contact the food. |
|
39
|
0.50
|
Wiping cloths: properly used and stored |
Yes |
No
|
No |
3-304.14(B) Hold in-use wiping cloths in sanitizer between uses. Observed wet wiping cloth stored on a prep surface. Item was returned to a sanitizer container by PIC. |
|
41
|
0.50
|
In-use utensils: properly stored |
Yes |
No
|
No |
3-304.12 Store in-use utensils in a clean, dry place, in food with handles out, in 135F or greater water or in running water which quickly moves food particles to the drain. Observed ice scoop in the front bar area stored inside the ice with the handle in contact with the food product. Item was spiked into the product by EHS and demonstrated to employee. |
|
45
|
1
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
Yes
|
No |
4-501.11 Maintain equipment in good repair. Observed rusted equipment such as shelving and tables. Observed damage dry fish, as well as chicken breading containers damaged.
4-501.12 Resurface or replace cutting surfaces that can no longer be effectively cleaned and sanitized. Observed cutting board on a flip top cooler unit in need of resurfacing/replacing. |
|
47
|
0.50
|
Non-food-contact surfaces clean |
No |
No
|
No |
4-601.11(C )/4-602.13 Keep the equipment clean to avoid build up of dust, food residue or debris. Observed grease and residue accumulation on equipment and surfaces in the kitchen area. |
|
53
|
0.50
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed floor and wall damage throughout facility.
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed accumlated areas of grease and food residue on several walls and floors in the kitchen area. |