| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
23
|
0
|
Proper date marking & disposition |
Yes |
No
|
No |
3-501.18 Discard the food requiring date labels once time/temperature window has expired, if it has not been labeled, or if the label is incorrect. -P The PIC should train and assign staff to monitor date marking to prevent the use of food products that are no longer in compliance with 3-501.17 (A), (B), or (C). Observed pimento cheese and pulled bbq chicken originally prepped on 9/23. CDI- PIC voluntarily discarded items.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Date Marking Food Safely https://youtu.be/BOPsSNUajYs . |
|
45
|
0
|
Single-use & single-service articles: properly stored & used |
No |
No
|
No |
4-903.11(A)(C) Store single-use and single-service articles in a clean, dry location; where they are not exposed to splash, dust, or other contamination; and at least 6 inches above the floor. Observed single use trays stored in metal container with heavy dust accumulation. Located by window on end of hot display. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed gaskets on prep unit in need of replacement. |
|
49
|
1
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed multiple plastic containers with old sticker residue still intact, racks used to store dishes above 3-comp, all needing to be cleaned. *REPEAT* |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed handsink at front of establishment, prep sink in kitchen area, both needing repair due to water spewing water when in use. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed the floor area under and around the fryers has residue and debris build-up and needs to be cleaned. Ceiling tiles annd vents needing cleaning due to excessive dust accumulation. Ensure frequent cleaning to prevent build-up. *REPEAT*
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed wall and baseboarding needing repair near handsinks. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-303.11 Provide required lighting intensity. Observed light in walk-in needing repair. |
|