16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back door has door stopper, not allowing door to self-close or latch onto pool deck.
*Permit item
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not audibly ringing back at time of inspection.
.2530(f) Emergency phone shall remain operable and ring back in case of emergency. Manager adjusted ringer and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Items within 3' of piping and equipment in pump room. Light out in chemical storage on left room. Buckets of chemicals on ground in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(6) Provide sufficient lighting in chemical storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Sinks not working properly with sensor for handwashing.
.2526(m) Keep restrooms and fixtures clean and in good repair. |