Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAQUA-TOTS SWIM SCHOOLS
Address11926 PROVIDENCE RD W
SUITE E-4
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/2/2023
Final Score @ Grade
12
General CommentsMain drains and skimmer equalizer lines expire November 2023. Replace main drain skimmer equalizers (or plug) and update PDSC form for approval prior to expiration to avoid immediate suspension of permit. Inspection Britney Vinson and Alixis Roccia Recommended bathers showering BEFORE classes and entering pool to help mitigate water clarity and scum accumulation in pool and skimmers.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Hair and debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned, emptied and corrected. 1 of 4 weirs missing at time of inspection. .2518(k) Replace missing weirs. Lack of severity does not warrant permit action at this time.
22 6 Premises: emergency telephone provided No No No Emergency phone off hook, inoperable at time of inspection. Signage missing dialing instructions and correct phone number. .2530(f) Emergency phone shall remain operable. Inspector adjusted and fixed phone. Corrected. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator added dialing instructions and phone number and corrected
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items within 3' of piping and equipment in pump room. Some chemicals stored in pump room and pool storage inside. Chemicals stored in pool storage inside, not locked room. Light out in chemical storage on left room. Water on floor in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Chemical storage shall be kept locked when not in use by the pool operator. .2534(6) Provide sufficient lighting in chemical storage room. .2533(d) Pump room floor shall be kept dry and free of standing water.