8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Hair and debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned, emptied and corrected.
1 of 4 weirs missing at time of inspection.
.2518(k) Replace missing weirs. Lack of severity does not warrant permit action at this time. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone off hook, inoperable at time of inspection. Signage missing dialing instructions and correct phone number.
.2530(f) Emergency phone shall remain operable. Inspector adjusted and fixed phone. Corrected.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Operator added dialing instructions and phone number and corrected |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Items within 3' of piping and equipment in pump room. Some chemicals stored in pump room and pool storage inside. Chemicals stored in pool storage inside, not locked room. Light out in chemical storage on left room. Water on floor in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Chemical storage shall be kept locked when not in use by the pool operator.
.2534(6) Provide sufficient lighting in chemical storage room.
.2533(d) Pump room floor shall be kept dry and free of standing water. |