Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAQUA-TOTS SWIM SCHOOLS
Address11926 PROVIDENCE RD W
SUITE E-4
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/18/2021
Final Score @ Grade
12
General CommentsNew heater installed. Ensure all proper permits were pulled for electrical work. CPO stated permits have been pulled for the work. No signature due to COVID. Inspection with Lauren Habig Report to BALLANTYNEGM@AQUA-TOTS.COM

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door from parking lot into pool area, not self-latching or alarmed when opened at time of inspection. This door usually remains locked. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator adjusted and corrected to self-close, self-latch. New doors are being installed in 2021. Ensure doors onto pool deck meet compliance.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Swim school items stored around pool within 5' of pool. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Operator moved items and corrected. General Comment: Deck starting to chip around "No Diving" tile by back of pool. Ensure offset does not reach greater than 1/2". .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No forced or cross ventilation in chemical storage at time of inspection. Light in one chemical storage not coming on. Some pool chemicals stored in room in pool enclosure with no ventilation and chemicals stored in pump room. Items within 3' of piping and equipment in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(6) Provide sufficient lighting in chemical storage room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No No labels on piping in pump room at time of inspection. .2518(d) Piping and valves shall be labeled with color codes or labels. *Note: Identify vacuum line and ensure it is OFF while pool is being used.