Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Digital records missing main drain checks.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
2 weirs missing at time of inspection.
.2518(k) Replace missing weirs.
30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Swim school items stored around pool within 5' of pool. Hole in deck creating offset more than 1/2".
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck at time of inspection.
.2518(g) Keep flow meter operational.
30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No forced or cross ventilation in chemical storage at time of inspection. Light in one chemical storage not coming on. Some pool chemicals stored in room in pool enclosure with no ventilation. Items within 3' of piping and equipment in pump room. Some water on floor in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.b.2534(6) Provide sufficient lighting in chemical storage room. |