NameAQUA-TOTS SWIM SCHOOLS
Address11926 PROVIDENCE RD W
SUITE E-4
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/3/2018
Final Score @ Grade
28
General CommentsITS for vacuum port cover. **Note: Aquastar P12 main drain covers (2) and Aquastar 6 Hp skimmer equalizer covers (4) expire in July 2019, according to Meck Co records. Operator stated main drains were changed in October 2018. Observed 12X12 Aquastar main drains in pool. Update PDSC information to reflect correct install dates and make/model within 7 days to avoid immediate suspension of permit for documentation for PDSC information.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine 0.2 ppm a time of inspection. Maintain chlorine at least 1.0 ppm. Corrected to 1.0 ppm.
4 6 Water quality: water temperature of heated pool No No No Water in pool 90.3 degrees F at time of inspection. Maintain pool temperature at 90 F or below. Corrected to 89.9 degrees F.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Total alkalinity not recorded. Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and added to records. Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy for demonstration not USCG approved. Provide USCG approved ring buoy. Removed from deck. Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Cap missing on vacuum port. Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Integral vacuum ports constructed after May 1, 2010 shall have self-closing caps designed to be opened with a tool. **30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when corrected to lift.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Provide backflow prevention device on hose bibb by pool.