2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine 0.2 ppm a time of inspection. Maintain chlorine at least 1.0 ppm. Corrected to 1.0 ppm. |
|
4
|
6
|
Water quality: water temperature of heated pool |
No |
No
|
No |
Water in pool 90.3 degrees F at time of inspection. Maintain pool temperature at 90 F or below. Corrected to 89.9 degrees F. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Total alkalinity not recorded. Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and added to records. Corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy for demonstration not USCG approved. Provide USCG approved ring buoy. Removed from deck. Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Cap missing on vacuum port. Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Integral vacuum ports constructed after May 1, 2010 shall have self-closing caps designed to be opened with a tool.
**30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when corrected to lift. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Provide backflow prevention device on hose bibb by pool. |