3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535 Must keep pH levels at 7.2-7.8. Observed pH levels at 8. Immediate suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535 Toatal akalinity and cyanuric acid shall be checked on a weekly basis. Observed TA and CA checked on record sheets about once every 10 days. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539 Pools shall supply proper documentation of safety compliance. Observed for on PDSC forms Hayward main drain covers for both filter and pool pump. During inspection observed Hayward WG1032-BHF and Hayward WG1048e. General Manager stated pool operator stated the WG1048e may be for the main pump but is not completely sure. Told him that those covers can not handle the gpm for the pump and may need to change it. Provided PDSC forms to fill out and send in for approval. Immediate suspension issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518 Keep flow meters in good repair. Observed flow meters for both pool and filtration returns not in working order. |