NameSKYE CONDOMINIUMS
Address222 S CALDWELL ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/8/2024
Final Score @ Grade
32
General CommentsInspection conducted with operator Stoney. Immediate suspension of permit issued due to missing emergency phone signage and pH greater than 7.8. Once items are corrected, call Hope McIntosh at 980-229-7549 for re-inspection. At that time, other items noted as intent to suspend items will be re-evaluated and if remain non-compliant, a 30 day intent to suspend the permit may be issued. Note: Metal gate post becoming loose - needs to be tightened to prevent issues with gate closure/latching.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool water pH at 8.0. *Immediate suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Missing numerous days of record checks over past 6 months. Multiple days missing cl readings. No main drain checks being documented. Pool records being maintained digitally- recommend written documentation until records are consistent.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Water level shall be maintained to assure skimmers are operable. Water level low - skimmer not operable. Raise water level to allow skimmer operation. Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment should be conveniently located. Ring buoy rope coiled/tangled and fixed to wall mount rendering buoy inaccessible. Operator corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed chairs less than 6' from pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Emergency phone information signage removed. Immediate suspension item.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(a) Provide restrooms at all pools except for hotels, motels, condominiums and apartments where pool use is restricted to guests and residents. Both restroom doors locked - operator does not have key. Restrooms currently inaccessible/unusable.