2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Operator added liquid chlorine directly to the pool. Unable to determine if chlorinator is working. - Immediate suspension item. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH below 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate Suspension item |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Main drains recently replaced with new Aquastar A10RCFRxxx covers. Updated PDSC form has not been submitted. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy damaged. .2530(a) Provide USCG approved ring buoy with 15 ft. rope. - Immediate Suspension item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed chairs less than 6' from pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Posted information must match what 911 has. - Immediate suspension item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leaks from the ceiling in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
Fan in the chemical storage room not working. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in men's restroom. .2626(j) Provide soap and soap dispenser, no glass, at each sink.
Sink faucet not running continuously and shutting off immediately in the men's restroom. Adjust so handwashing can occur as required. .2626(m) Keep restrooms and fixtures clean and in good repair. |