3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH below 6.8. Maintain at 7.2 to 7.8. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Could not view log book due to pump room being inaccessible. Ensure daily record keeping for main drain checks, chlorine, and pH. Weekly alkalinity and acid checks.
Cyanuric acid reading above 100 ppm. May be affecting pool pH. Max level for cyanuric acid required at 100 ppm or less.
Some reagents expired in test kit. Provide new reagents. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Could not verify pump in pump room due to no access to pump room. Immediate Suspension issued. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some damage to plaster at bench and steps. Repair damage/plaster. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Damaged ring buoy and rope. Replace with USCG approved ring buoy and 15 ft. rope. Immediate Suspension issued. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Plant outside of gate entry provided foothold. Moved during inspection. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone not operable. Busy signal. Per operator, flood knocked out phone line. Phone shall be operable and capable of dialing 911. 911 shall have correct phone number and address. Immediate Suspension issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
No access to pump room. Per deed agreements, pump room shall be accessible at all times. Permit will be suspended if not accessible. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Faucet handle in men's restroom not staying engaged to properly handwash. Repair spring so that water runs continuously for proper handwashing. |