Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSKYE CONDOMINIUMS
Address222 S CALDWELL ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/14/2019
Final Score @ Grade
32
General CommentsNote: Access to pump room was not provided immediately to room beside pump room. Had to get permission from resident. Pump room access through room must be accessible at all times or permit will be suspended. Door into pump room baricaded shut with stopper. Removed during inspection and kept locked. Ring buoy damaged. Replace within 30 days. Intent to suspend issued for record keeping for CYA and main drains, paver damage, and flow meter replacement.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 6.8. Corrected to 7.6 during inspection. .2535(1) Maintain pH at 7.2 to 7.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Log book is digital. Does not show Cyanuric acid or main drain checks. Intent to Suspend issued. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool plaster on steps and bench beginning to wear/etched. .2537(14) Keep pool surface and pool floor free of debris.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope at 13.5 ft. Required at 15 ft. Corrected to 15 ft. during inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damaged paver next to pool. Cracked in multiple locations. Intent to Suspend issued. Damaged paver near shower outside of required decking. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter numbers worn off. Provide operable flow meter. Intent to Suspend issued. .2518(g) Flow meter be capable of measuring 1.5 times the design flow rate.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Soda ash on chemical storage room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in restrooms. .2626(j) Provide soap and soap dispenser, no glass, at each sink. Sink faucet not running continuously and shutting off immediately in the men's restroom. Adjust so handwashing can occur as required. .2626(m) Keep restrooms and fixtures clean and in good repair.