5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
pH, chlorine, and main drains must be checked once a day when the pool is open. Total Alkalinity and Cyanuric Acid (if in use) must be checked once a week, 100ppm maximum. Observed some gaps in pool records. Staff was advised of gaps and requirements. No Permit Action taken. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 2 skimmer weirs missing out of 7 skimmers total. Replace the missing weirs. No Permit Action taken. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladders to be missing the rubber foot bumpers. Replace the bumpers. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed two missing return eyeball fittings. Replace missing fittings. Most eyeball fittings in place. No Permit Action taken. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no air gap at the back wash line. |