Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAURORA FLATS
Address1427 EASTCREST DRIVE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/22/2019
Final Score @ Grade
14
General CommentsIntent to suspend issued for gate from grill area to pool deck. Call Chris Sells when repairs are complete at 704 576 8678. Pool will be closed in 30 days if the gate repairs are not completed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed one missing return fitting. Corrected during inspection. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed new gate installed on fence for grill area that leads off of pool dec. Gate locked at time of inspection. Newly installed gate provides access from outside pool deck to pool deck. Gate previously not regulated that leads from grill area to pool deck is now considered enterence to pool deck and does not meet requirements. Gate from grill area to pool deck has latch below 54" and swings toward the pool. .2528(a) Gate latches shall be 54" in height. .2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Intent to suspend issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed one filter pressure gauge not properly functioning. .2519(k) Provide operational pressure gauge on filter. Intent to suspend.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed pump in structure with only 3 walls. .2533(a) Pump room shall contain at least all pumps, chemical feeding equipment, and other mechanical and electrical equipment.