Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameADDISON AT SOUTH TRYON, THE
Address7000 MODERN WAY
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/28/2026
Final Score @ Grade
18
General CommentsInspection conducted with operator Avery. All permit items in compliance by end of inspection. Permit issued and will be available for printing from the Mecklenburg County Pool website. No Night Swimming. Note: Various areas of deck tile offset and/or offset of pool coping observed around pool perimeter approaching 1/2”, some damaged deck tiles within 6’ of pool edge, and cracked depth marker near sun shelf - repair or replace prior to permitting 2027.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 2 of 6 weirs missing in skimmers. One weir installed backwards, not functional. Replace missing weirs and correct improperly installed weir.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Ring buoy missing rope. Replaced during inspection. Body hook attached to pole less than 12’. Corrected to 12’ pole during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm. Observed both doors leading from clubhouse directly onto pool deck with latching device disabled. Operator corrected - doors both latch shut at end of inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Light burned out in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap in women’s restroom.