Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameADDISON AT SOUTH TRYON, THE
Address7000 MODERN WAY
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/2/2025
Final Score @ Grade
16
General CommentsConducted inspection with Marcus Stroman. Intent to suspend issued for gate latches and records. Items must be corrected within 30 days or permit may be suspended. Call EHS Devon when ready for re inspection 7049981122 No night swimming. Const. Date: 4/2/2014 Rope Length: 50' On 4/26/24 Caribbean Pool Service installed (1) 400000 housing to replace cracked housing on the existing Pentair pump. No listed permit conditions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Records inconsistent. Record sheet missing spot for cyanuric acid and daily drain checks. Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. End caps missing on ladder. Replace.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope too long. CPO corrected to 50ft. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. New magnetic latches protrude more than 2inches on gates at 42” off ground creating footholds. Raise the magnetic latches 48” off ground or install a slanted piece of metal above foothold. Intent to suspend item