Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameADDISON AT SOUTH TRYON, THE
Address7000 MODERN WAY
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/1/2023
Final Score @ Grade
24
General CommentsInspection conducted with John Dalton. 30 day intent to suspend the permit issued for broken vacuum line covers and record keeping. Once items have been corrected, call Hope McIntosh at 980-229-7549 for a re-visit. If not corrected within 30 days, permit will be suspended. Night swimming not approved at this time. Modify pool hours to dawn until dusk until night swimming would be approved. Call Hope McIntosh if night swimming appointment is desired. Equalizer covers expire 2/19/2024. Replace covers and submit PDSC for approval prior to expiration or disable skimmers per state recommendations.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Chlorine in pool at .08. Corrected to 2.0 during inspection.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No TA recorded since 8/22. Records do not match actual water chemistry of pool. Ensure cl, pH, and main drain checks daily with CYA and TA checked at least weekly. Test water from pool and ensure accurately documented on records. *permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers with accumulated debris. Cleaned during inspection..2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Locking caps on vacuum ports broken. Replace. *permit item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Gate near fitness area/bathrooms not latching closed and overhead garage door not limited or fixed closed. Corrected during inspection
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Bag of dry chemical on floor of chemical room. Liquid chemicals stored above dry chemcials.