| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Skimmer equalizer lines observed plugged in skimmers in all equalizer lines, 4 HP on all pool walls. No suction hazard present, but PDSC form must be updated to reflect what is in pool. Allowed 30 days to correct and submit updated PDSC form or remove plugs. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
*Permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Weirs missing at time of inspection.
.2518(k) Replace missing weirs.
*Permit item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy and body hook behind wall and rose bushes starting to grow over path to emergency equipment. .2530(a) Lifesaving equipment should be conveniently located. Keep accessible. Advised moving equipment or cutting back shrubs for accessibility. Due to life saving equipment being available, allowed 30 days for correction of location/accessibility.
*permit item |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Multiple gates not latching at time of inspection. Two windows in administrative area did not have stoppers in window and able to open greater than 4" onto pool deck. Fencing in some areas have shrubs that have grown and fence is not 48" in height from outside barrier of fence.
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
*Permit item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
"FT" tiling not secured to deck at time of inspection, creating trip hazard.
.2537(2) Decks shall be kept in good repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
One sign at pool faded and not clearly visible with "Adults should not swim alone" and "Children should not use the swimming pool without adult supervision" 1" in height. Replace or remove. Other signage meets requirement, but may not be visible from all areas of pool deck. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
*Permit item |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Light fixture protruding from wall at time of inspection, creating hazard. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard.
*Permit item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Large plants in front of emergency phone and signage, making phone inaccessible.
.2530(f) Emergency phone shall be accessible to all pool users. Moved plants slightly and phone can now be accessed for use, but requires permanent compliance. Allowed 30 days for correction of location/accessibility.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemical room lock broken and not locked at time of inspection. .2533(a) The equipment and chemical room door shall have a permanent lock and be kept locked when not in use by the pool operator. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Labels fading on piping. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower off at time of inspection. .2526(h) Shower(s) shall be provided. Operator turned water on and shower worked, but part is being replaced. |